battery low
This block is part of the globals group and was last modified in core v15.0.0.
battery low v15.0.0 Starts the flow when a device's battery drops below the threshold, or reports its own low-battery flag.
- device
valuev15.0.0Only fire for this device. Leave empty for every battery device.
- room
valuev15.0.0Only fire for devices in this room. Leave empty for every room.
- below %
numberv15.0.0Fire when the battery crosses below this percentage.
- flow
v15.0.0 - device
objectv15.0.0The full device: id, name, room, type, capabilities, current state.
- device id
valuev15.0.0Stable platform id, e.g. zigbee:0x00158d0007e1a2b3.
- name
valuev15.0.0The device's friendly name.
- room
valuev15.0.0The room the device is assigned to, empty if none.
- type
valuev15.0.0sensor, light, switch, climate, cover, lock or button.
- capability
valuev15.0.0Which capability changed, e.g. occupancy, contact, power.
- value
valuev15.0.0The new value.
- previous
valuev15.0.0The value before this change, empty on the first report.
- at
numberv15.0.0Unix seconds the device reported.
Start-of-flow trigger for device health. Fires when battery percentage crosses below `below` (default 20), OR when a device raises its own battery_low flag. Both dialects are handled because devices implement one or the other, rarely both.
zigbee |
zwave |
matter |
battery |
maintenance |
trigger |
A typical wiring for battery low: the flow out pin feeds debug.
Used in these guides
These documentation pages use or explain this block:
Version history
Introduced in v15.0.0.
Back to
globals Return to the main group to view all sub-groups Back to home Return to the group to view all blocks within this group 